Rm 218, Tangxing Digital Bld, #6 Tangxing Rd, Xi’an, Shaanxi, China +86 17791258855 [email protected]
Curcumin fails in three distinct ways, and each one has a different fix. Treating them as a single "stability" problem is why some formulations still fade after the obvious changes.
| Route | Trigger | What you see | What slows it |
|---|---|---|---|
| Hydrolysis | Neutral to alkaline pH, water activity | Assay loss, colour shifts brown, bitter off-note | Keep pH acidic (below ~5), reduce water activity, shorten time at temperature |
| Photodegradation | UV and visible light, transparent packaging | Fading, uneven colour in the pack | Opaque or amber packaging, light-protective secondary carton |
| Oxidation | Oxygen, trace metals, heat | Browning, loss of the characteristic yellow | Nitrogen flush, chelating agents, antioxidants, lower storage temperature |
In water at neutral pH, curcumin hydrolysis is fast — measured in hours or less in published buffer studies, not months. That is the single most important fact for anyone putting curcumin into a ready-to-drink product. In dry powder, with water activity below 0.3, the same molecule is stable for years.
Our standard claim is 24 months, unopened, stored at or below 25 °C, protected from light and moisture. That claim is not a formality; it is what the packaging and the storage conditions have to deliver together.
The 24-month clock applies to the unopened pack. Once a drum is opened, moisture and oxygen enter. We recommend using an opened drum within 30 days, resealing with the liner folded and a desiccant sachet, or repacking into smaller foil units at the customer's site.
We run the standard ICH conditions, plus a photostability arm and an in-matrix arm when the customer's application is known. The protocol below is the structure; the report is batch-specific.
| Arm | Condition | Timepoints | Tests |
|---|---|---|---|
| Long term | 25 °C / 60% RH | 0, 3, 6, 12, 18, 24 months | Assay, profile, LOD, colour, micro |
| Intermediate | 30 °C / 65% RH | 0, 6, 12 months | Assay, profile, LOD, colour |
| Accelerated | 40 °C / 75% RH | 0, 1, 2, 3, 6 months | Assay, profile, LOD, colour, micro |
| Photostability | ICH Q1B, option 2 | 0, and end of exposure | Assay, colour (ΔE) |
| In matrix | pH 3 / 5 / 7, 4 °C and 40 °C | 0, 1, 2, 4 weeks | Assay, colour, haze, pH |
The in-matrix arm is only meaningful when we know the real formula, the process temperature and the packaging. Send those three and the study design changes.
Batch-specific stability reports are available on request. The protocol above is what each report follows; we do not publish average values from other batches.
Three variables decide whether a curcumin system survives, and only one of them is the raw material:
Ask for "assay retention at 12 months in the finished matrix", not "shelf life 24 months" for the raw material. The raw material claim and the finished-product claim are different numbers, and the customer's audit will ask for the second one.
To design a stability arm for your product, send:
We will come back with a study design, a timeline and the test panel. For most matrices, a four-week in-matrix arm answers the go/no-go question before a full ICH study is justified.